Brocade Switches
Alteeve Wiki :: How To :: Brocade Switches |
Validated Switches
The following switches (and firmwares) have been validates to work with the Anvil!:
- ICX6610
- 7.40d
- ICX6450
- 7.40a
- 7.40e
- 8.00a
Serial Connection
Note: Depending on your terminal emulator, the <Backspace> key may not work. If it doesn't, try pressing ctrl + h to delete the character to the left of your cursor. |
You can use screen to connect to the switch (default values are fine). The example below is what you would use on most servers with an on-board serial port. If you have two, then port two would be /dev/ttyS1. If you are using a USB to serial adapter, then you will use /dev/ttyUSB0 (or if it is a multi-port adapter, /dev/ttyUSB1, etc). If none of these work, you will need to consult your operating system documentation and/or serial port adapter to determine the proper /dev/ttyX device to use.
screen /dev/ttySO
The screen will be blank until you press <enter>.
ICX6610-48 Switch>
To log in;
ICX6610-48 Switch>enable
No password has been assigned yet...
There is no default user name and password.
Exiting screen
To end your screen session, press ctrl + a together, release and then press k.
You will be asked if you want to kill the session, press y to confirm.
Really kill this window [y/n]
[screen is terminating]
Configure a Password
To use the web interface later, a user and password needs to be set.
Note: Super User level password can be an alphanumeric string, but cannot begin with a number. |
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#enable super-user-password secret
ICX6610-48 Switch(config)#enable user disable-on-login-failure 10
ICX6610-48 Switch(config)#user alteeve privilege 0 password secret
ICX6610-48 Switch(config)#show users
Username Password Encrypt Priv Status Expire Time
======================================================================================================================
alteeve $1$HF4..Zv.$uF.PUT.bqkMy5GicUIrhG/ enabled 0 enabled Never
To enable the web interface;
ICX6610-48 Switch(config)#aaa authentication web-server default local
ICX6610-48 Switch(config)#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Form the Stack
ICX6450 and ICX6610
ICX6610-48 Switch>enable
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/6 is not available.
ICX6610-48 Switch(config)#exit
ICX6610-48 Switch#stack secure-setup
Discovering the stack topology...
Current Discovered Topology - RING
Available UPSTREAM units
Hop(s) Id Type Mac Address
1 new ICX6610-48 xxxx.xxxx.xxxx
Available DOWNSTREAM units
Hop(s) Id Type Mac Address
1 new ICX6610-48 xxxx.xxxx.xxxx
Do you accept the topology (RING) (y/n)?: y
Selected Topology:
Active Id Type Mac Address
1 ICX6610-48 yyyy.yyyy.yyyy
Selected UPSTREAM units
Hop(s) Id Type Mac Address
1 2 ICX6610-48 xxxx.xxxx.xxxx
Selected DOWNSTREAM units
Hop(s) Id Type Mac Address
1 2 ICX6610-48 xxxx.xxxx.xxxx
Do you accept the unit id's (y/n)?: y
T=1d20h24m2.8: Election, was alone --> active, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
T=1d20h24m3.5: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
reset unit 2: u2 diff bootup id=1
Unit 1 loses all neighbors.
Active unit 1 deletes u2 and its config because it is learned.
Config changed due to add/del units. Do write mem if you want to keep it
(switch reboots)
T=1d20h26m43.2: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
Done hot swap: active controller unit 1 sets unit 2 to Ready.
Config changed due to add/del units. Do write mem if you want to keep it
ICX6610-48 Switch#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
A moment later, more boot messages.
Stack unit 2 Power supply 1 is up
Stack unit 2 Power supply 2 is up
Assigned unit 2 to be standby
start running config sync
Running config sync to standby is complete
ICX6610-48 Switch#show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-48 active xxxx.xxxx.xxxx 128 local Ready
2 S ICX6610-48 standby yyyy.yyyy.yyyy 0 remote Ready
active standby
+---+ +---+
=2/1| 1 |2/6==2/1| 2 |2/6=
| +---+ +---+ |
| |
|------------------------|
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is xxxx.xxxx.xxxx
Note: no "stack mac" config. My MAC will change after failover.
Configure the stack to handle switch "hitless" failure and recovery.
ICX6610-48 Switch#config terminal
ICX6610-48 Switch(config)#hitless-failover enable
Assign a static MAC to the stack. In this case, I always copy stack unit 1's real MAC address.
ICX6610-48 Switch(config)#stack mac cc4e.24b9.5624
Last, switch to unit 2 and change it's priority to match the priority of unit 1.
ICX6610-48 Switch(config)#stack unit 2
ICX6610-48 Switch(config-unit-2)#priority 128
Priority change needs 120 seconds to take effect.
ICX6610-48 Switch(config-unit-2)#exit
ICX6610-48 Switch(config)#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Two minutes after you change the stack priority, the switch run an election.
Will do election in 30 sec due to priority change
Will do election in 10 sec due to priority change
T=1d20h35m20.2: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
Verify the stack is configured the way we want.
ICX6610-48 Switch(config)#show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-48 active xxxx.xxxx.xxxx 128 local Ready
2 S ICX6610-48 standby yyyy.yyyy.yyyy 128 remote Ready
active standby
+---+ +---+
=2/1| 1 |2/6==2/1| 2 |2/6=
| +---+ +---+ |
| |
|------------------------|
Standby u2 - protocols ready, can failover or manually switch over
Current stack management MAC is xxxx.xxxx.xxxx
Excellent, done.
ICX6430-C12
The ICX6430-C12 doesn't support stacking. However, a stack can be somewhat simulated by tagging a dedicated port with all our VLANs. This will allow traffic from any VLAN to use the same "uplink" port. Also, without a proper stack, we can not create a trunk/LAG. So we enable rapid STP on each switch's customer-facing uplink port instead.
Enable Jumbo Frames
The ICX6610 support packets up to 10240 bytes. That is to say, if jumbo frames are enabled, the MTU of the switch is 10 KiB.
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#jumbo
Jumbo mode setting requires a reload to take effect!
ICX6610-48 Switch(config)#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
ICX6610-48 Switch(config)#exit
ICX6610-48 Switch#reload
Are you sure? (enter 'y' or 'n'): y
Reload request sent to attached stack member(s)...
Rebooting(0)...
Assign IP to Switch
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#ip address 10.20.1.5 255.255.0.0
ICX6610-48 Switch(config)#exit
The router is at 10.20.255.254, so ping that to verify the IP is configured.
ICX6610-48 Switch#ping 10.20.255.254
Sending 1, 16-byte ICMP Echo to 10.20.255.254, timeout 5000 msec, TTL 64
Type Control-c to abort
Reply from 10.20.255.254 : bytes=16 time<1ms TTL=64
Success rate is 100 percent (1/1), round-trip min/avg/max=0/0/0 ms.
Good, save the changes.
ICX6610-48 Switch#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Update the firmware
Warning: Be sure to have your switches on UPSes before flashing them! As with all devices, a power loss during the flash process may cause the switch to become unusable. |
Selecting the Firmware Version
Before we start, we need to decide what version of the firmware we want to install. To do this, start by logging in to your switch(es) and check their current firmware version.
ICX6610-48 Switch#show flash
Stack unit 1:
Compressed Pri Code size = 5370497, Version:07.3.00fT7f1 (/foundry/FGS/os/FCXS07300f.bin)
Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
Code Flash Free Space = 52822016
Stack unit 2:
Compressed Pri Code size = 5370497, Version 07.3.00fT7f1 (/foundry/FGS/os/FCXS07300f.bin)
Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
Code Flash Free Space = 52822016
Note that both switches are running the major version 07.3.00f. Being that we're interested in High Availability, we are going to be conservative and upgrade to the latest subversion available. Both switches are 7.3, so that is what we will use. If one had been 7.4, for example, then we would have upgraded both to the latest 7.4 version.
Layer 2 vs Layer 3
These switches have two firmwares;
- Layer 2 (S); This is seen in the above output in the current version's flash file "/foundry/FGS/os/FCXS07300f.bin".
- Layer 3 (R); This is seen in the above output in the current version's flash file "/foundry/FGS/os/FCXR07300f.bin".
We're only going to update the layer 2 "S" firmware. We don't use the layer 3 features for HA so we won't update them. If you want to updated them, that is fine. The upgrade process below is easily ported to the layer 3 firmware update process.
Downloading the Firmware
To get the firmware:
- Go to Ruckus Downloads.
- Find the switch you have and click to download the firmware.
- Login (create a ruckus account, if needed)
- Save the file on your computer.
Extracting the Image
Navigate to the downloaded file. It will be a .zip file. Expand it. This will create several directories.
To upload the firmware, we need to copy the image to the root of our TFTP server (/var/lib/tftpboot/ on EL6).
Browse into the extracted 07300j/ICX/Images/ directory (or the matching directory for your firmware). You will see two file:
cd 07300j/ICX/Images/
ls -lah
total 12M
drwxr-xr-x 2 root root 4.0K May 8 2014 .
drwxr-xr-x 8 root root 4.0K May 9 2014 ..
-rwxr-xr-x 1 root root 6.7M May 8 2014 FCXR07300j.bin
-rwxr-xr-x 1 root root 5.2M May 8 2014 FCXS07300j.bin
As discussed above, we will be upgrading the layer 2 "S" image. So this is the file we will copy to the TFTP root directory.
cp FCXS07300j.bin /var/lib/tftpboot/
ls -lah /var/lib/tftpboot/FCXS07300j.bin
Performing the Flash
Note: We will be flashing both switches at once as they are stacked. |
We're ready to flash! So it's time to log into the switch.
ICX6610-48 Switch#copy tftp flash 10.20.255.254 FCXS07300j.bin primary
Flash Memory Write (8192 bytes per dot)
Automatic copy to member units: 2
....<lots of dots>....
TFTP to Flash Done.
ICX6610-48 Switch#show flash
Stack unit 1:
Compressed Pri Code size = 5430491, Version:07.3.00jT7f1 (FCXS07300j.bin)
Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
Code Flash Free Space = 52690944
Stack unit 2:
Compressed Pri Code size = 5430491, Version 07.3.00jT7f1 (FCXS07300j.bin)
Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
Code Flash Free Space = 52690944
Reboot to load the new firmware.
ICX6610-48 Switch#write memory
ICX6610-48 Switch#reload
Are you sure? (enter 'y' or 'n'): y
Note: It takes a while to reboot because it will update the firmware of the second node. Please be patient. |
ICX6610-48 Switch#show flash
Stack unit 1:
Compressed Pri Code size = 5430491, Version:07.3.00jT7f1 (FCXS07300j.bin)
Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
Code Flash Free Space = 52690944
Stack unit 2:
Compressed Pri Code size = 5430491, Version 07.3.00jT7f1 (FCXS07300j.bin)
Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
Code Flash Free Space = 52690944
Done!
Configure VLAN
VLANs provide a way of dividing up a switch (or stack of switches) into multiple, isolated switches (this is actually somewhat simplistic, but it gets the idea across). Traffic from one VLAN segment can not reach ports allocated to another VLAN, providing a useful layer of security.
Planning
We're creating three separate VLANs;
By default, all ports default to VID 1. If you want to improve security, you can leave all unused ports on VID 1. In this tutorial, we need to allocate all ports for use by other equipment.
Before you start, you need to decide how you want to assign physical ports on your switches to VLAN IDs. I like to do this by creating a table showing all the ports, label their external port numbers and logical numbers and then write in what will be plugged into each port. With this, it's fairly easy to mark what ports will be assigned to what VLANs.
Cabling a pair of ICX7250-24
In this example, we're showing how to cable up a pair of Brocade (Ruckus) ICX7250-24 switches in a very typical configuration. It can drive two Anvil! systems along with the usual foundation pack.
an-switch01 | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Back-Channel Network]] | Storage Network | Internet-Facing Network | Stack | unused | ||||||||||||||
1 (1/1/1) | 3 (1/1/3) | 5 (1/1/5) | 7 (1/1/7) | 9 (1/1/9) | 11 (1/1/11) | 13 (1/1/13) | 15 (1/1/15) | 17 (1/1/17) | 19 (1/1/19) | 21 (1/1/21) | 23 (1/1/23) | X1 (1/2/1) | X3 (1/2/3) | X5 (1/2/5) | X7 (1/2/7) | |||
an-a01n01 BCN - Link 1 |
an-a01n01 IPMI / Fencing |
an-a02n01 BCN - Link 1 |
an-a02n01 IPMI / Fencing |
an-striker01 BCN - Link 1 |
an-a01n01 SN - Link 1 |
an-a02n01 SN - Link 1 |
an-a01n01 IFN - Link 1 |
an-a02n01 IFN - Link 1 |
an-striker01 IFN - Link 1 |
-- | -- | To an-switch02 X1 |
To an-switch02 X3 |
-- | -- | |||
an-a01n02 BCN - Link 1 |
an-a01n02 IPMI / Fencing |
an-a02n02 BCN - Link 1 |
an-a02n02 IPMI / Fencing |
-- | an-a01n02 SN - Link 1 |
an-a02n02 SN - Link 1 |
an-a01n02 IFN - Link 1 |
an-a02n02 IFN - Link 1 |
-- | -- | Primary Uplink 1 |
To an-switch02 X2 |
To an-switch02 X4 |
-- | -- | |||
2 (1/1/2) | 4 (1/1/4) | 6 (1/1/6) | 8 (1/1/8) | 10 (1/1/10) | 12 (1/1/12) | 14 (1/1/14) | 16 (1/1/16) | 18 (1/1/18) | 20 (1/1/20) | 22 (1/1/22) | 24 (1/1/24) | X2 (1/2/2) | X4 (1/2/4) | X6 (1/2/6) | X8 (1/2/8) | |||
VID 100 | VID 200 | VID 300 | Stack | unused | ||||||||||||||
an-switch02 | ||||||||||||||||||
Back-Channel Network]] | Storage Network | Internet-Facing Network | Stack | unused | ||||||||||||||
1 (2/1/1) | 3 (2/1/3) | 5 (2/1/5) | 7 (2/1/7) | 9 (2/1/9) | 11 (2/1/11) | 13 (2/1/13) | 15 (2/1/15) | 17 (2/1/17) | 19 (2/1/19) | 21 (2/1/21) | 23 (2/1/23) | X1 (2/2/1) | X3 (2/2/3) | X5 (2/2/5) | X7 (2/2/7) | |||
an-a01n01 BCN - Link 2 |
an-pdu01 | an-a02n01 BCN - Link 2 |
an-ups01 | an-striker02 BCN - Link 1 |
an-a01n01 SN - Link 2 |
an-a02n01 SN - Link 2 |
an-a01n01 IFN - Link 2 |
an-a02n01 IFN - Link 2 |
an-striker01 IFN - Link 2 |
-- | -- | To an-switch01 X1 |
To an-switch01 X3 |
-- | -- | |||
an-a01n02 BCN - Link 2 |
an-pdu02 | an-a02n02 BCN - Link 2 |
an-ups02 | -- | an-a01n02 SN - Link 2 |
an-a02n02 SN - Link 2 |
an-a01n02 IFN - Link 2 |
an-a02n02 IFN - Link 2 |
-- | -- | Alternate Uplink 1 |
To an-switch01 X2 |
To an-switch01 X4 |
-- | -- | |||
2 (2/1/2) | 4 (2/1/4) | 6 (2/1/6) | 8 (2/1/8) | 10 (2/1/10) | 12 (2/1/12) | 14 (2/1/14) | 16 (2/1/16) | 18 (2/1/18) | 20 (2/1/20) | 22 (2/1/22) | 24 (2/1/24) | X2 (2/2/2) | X4 (2/2/4) | X6 (2/2/6) | X8 (2/2/8) | |||
VID 100 | VID 200 | VID 300 | Stack | unused |
Cabling a pair of ICX6450-24
In this example, we're showing how to cable up a pair of ICX6450-24 switches in a very typical configuration. It can drive two Anvil! systems along with the usual foundation pack.
an-switch01 | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stack | Back-Channel Network]] | Storage Network | Internet-Facing Network | |||||||||||||
X1 (1/2/1) | X3 (1/2/3) | 1 (1/1/1) | 3 (1/1/3) | 5 (1/1/5) | 7 (1/1/7) | 9 (1/1/9) | 11 (1/1/11) | 13 (1/1/13) | 15 (1/1/15) | 17 (1/1/17) | 19 (1/1/19) | 21 (1/1/21) | 23 (1/1/23) | |||
To an-switch02 X3 |
To an-switch02 X1 |
an-a01n01 BCN - Link 1 |
an-a01n01 IPMI / Fencing |
an-a02n01 BCN - Link 1 |
an-a02n01 IPMI / Fencing |
an-striker01 BCN - Link 1 |
an-a01n01 SN - Link 1 |
an-a02n01 SN - Link 1 |
an-a01n01 IFN - Link 1 |
an-a02n01 IFN - Link 1 |
an-striker01 IFN - Link 1 |
-- | -- | |||
-- | -- | an-a01n02 BCN - Link 1 |
an-a01n02 IPMI / Fencing |
an-a02n02 BCN - Link 1 |
an-a02n02 IPMI / Fencing |
-- | an-a01n02 SN - Link 1 |
an-a02n02 SN - Link 1 |
an-a01n02 IFN - Link 1 |
an-a02n02 IFN - Link 1 |
-- | -- | Uplink 1 | |||
X2 (1/2/2) | X4 (1/2/4) | 2 (1/1/2) | 4 (1/1/4) | 6 (1/1/6) | 8 (1/1/8) | 10 (1/1/10) | 12 (1/1/12) | 14 (1/1/14) | 16 (1/1/16) | 18 (1/1/18) | 20 (1/1/20) | 22 (1/1/22) | 24 (1/1/24) | |||
Unused | VID 100 | VID 200 | VID 300 | |||||||||||||
an-switch02 | ||||||||||||||||
Stack | Back-Channel Network]] | Storage Network | Internet-Facing Network | |||||||||||||
X1 (2/2/1) | X3 (2/2/3) | 1 (2/1/1) | 3 (2/1/3) | 5 (2/1/5) | 7 (2/1/7) | 9 (2/1/9) | 11 (2/1/11) | 13 (2/1/13) | 15 (2/1/15) | 17 (2/1/17) | 19 (2/1/19) | 21 (2/1/21) | 23 (2/1/23) | |||
To an-switch01 X3 |
To an-switch01 X1 |
an-a01n01 BCN - Link 2 |
an-pdu01 | an-a02n01 BCN - Link 2 |
an-ups01 | an-striker02 BCN - Link 1 |
an-a01n01 SN - Link 2 |
an-a02n01 SN - Link 2 |
an-a01n01 IFN - Link 2 |
an-a02n01 IFN - Link 2 |
an-striker02 IFN - Link 1 |
-- | -- | |||
-- | -- | an-a01n02 BCN - Link 2 |
an-pdu02 | an-a02n02 BCN - Link 2 |
an-ups02 | -- | an-a01n02 SN - Link 2 |
an-a02n02 SN - Link 2 |
an-a01n02 IFN - Link 2 |
an-a02n02 IFN - Link 2 |
-- | -- | Uplink 2 | |||
X2 (2/2/2) | X4 (2/2/4) | 2 (2/1/2) | 4 (2/1/4) | 6 (2/1/6) | 8 (2/1/8) | 10 (2/1/10) | 12 (2/1/12) | 14 (2/1/14) | 16 (2/1/16) | 18 (2/1/18) | 20 (2/1/20) | 22 (2/1/22) | 24 (2/1/24) | |||
Unused | VID 100 | VID 200 | VID 300 |
Cabling a pair of ICX6610-48
In this example, we're showing how to cable up a pair of ICX6610-48 switches in a rather unusual configuration. It is driving just one Anvil!, but that Anvil! is using 10 Gbps SFP+ links. The switches are going to be populated with non-Anvil! equipment.
What you will configure will, of course, totally vary. The specific ports aren't the point, the planning and implementation are.
an-switch01 | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BCN | SN | IFN | Back-Channel Network | Internet-Facing Network | ||||||||||||||||||||||||||
X1 (1/2/1) | X3 (1/2/3) | X5 (1/2/5) | X7 (1/2/7) | 1 (1/1/1) | 3 (1/1/3) | 5 (1/1/5) | 7 (1/1/7) | 9 (1/1/9) | 11 (1/1/11) | 13 (1/1/13) | 15 (1/1/15) | 17 (1/1/17) | 19 (1/1/19) | 21 (1/1/21) | 23 (1/1/23) | 25 (1/1/25) | 27 (1/1/27) | 29 (1/1/29) | 31 (1/1/31) | 33 (1/1/33) | 35 (1/1/35) | 37 (1/1/37) | 39 (1/1/39) | 41 (1/1/41) | 43 (1/1/43) | 45 (1/1/45) | 47 (1/1/47) | |||
an-a05n01 BCN - Link 1 |
an-a05n01 SN - Link 1 |
an-a05n01 IFN - Link 1 |
an-a05n01 BCN - Link 3 |
an-a05n01 IPMI / Fencing |
an-striker01 BCN - Link 1 |
an-striker01 IPMI |
an-a05n01 IFN - Link 3 |
an-striker01 IFN - Link 1 |
||||||||||||||||||||||
X2 (1/2/2) | X4 (1/2/4) | X6 (1/2/6) | X8 (1/2/8) | 2 (1/1/2) | 4 (1/1/4) | 6 (1/1/6) | 8 (1/1/8) | 10 (1/1/10) | 12 (1/1/12) | 14 (1/1/14) | 16 (1/1/16) | 18 (1/1/18) | 20 (1/1/20) | 22 (1/1/22) | 24 (1/1/24) | 26 (1/1/26) | 28 (1/1/28) | 30 (1/1/30) | 32 (1/1/32) | 34 (1/1/34) | 36 (1/1/36) | 38 (1/1/38) | 40 (1/1/40) | 42 (1/1/42) | 44 (1/1/44) | 46 (1/1/46) | 48 (1/1/48) | |||
an-a05n02 BCN - Link 1 |
an-a05n02 SN - Link 1 |
an-a05n02 IFN - Link 1 |
an-a05n02 BCN - Link 3 |
an-a05n02 IPMI / Fencing |
an-striker02 BCN - Link 1 |
an-a05n02 IFN - Link 3 |
an-striker02 BCN - Link 1 |
Uplink 1 | ||||||||||||||||||||||
VID 100 | VID 200 | VID 300 | VID 100 | VID 300 | ||||||||||||||||||||||||||
an-switch02 | ||||||||||||||||||||||||||||||
BCN | SN | IFN | Back-Channel Network | Internet-Facing Network | ||||||||||||||||||||||||||
X1 (2/2/1) | X3 (2/2/3) | X5 (2/2/5) | X7 (2/2/7) | 1 (2/1/1) | 3 (2/1/3) | 5 (2/1/5) | 7 (2/1/7) | 9 (2/1/9) | 11 (2/1/11) | 13 (2/1/13) | 15 (2/1/15) | 17 (2/1/17) | 19 (2/1/19) | 21 (2/1/21) | 23 (2/1/23) | 25 (2/1/25) | 27 (2/1/27) | 29 (2/1/29) | 31 (2/1/31) | 33 (2/1/33) | 35 (2/1/35) | 37 (2/1/37) | 39 (2/1/39) | 41 (2/1/41) | 43 (2/1/43) | 45 (2/1/45) | 47 (2/1/47) | |||
an-a05n01 BCN - Link 2 |
an-a05n01 SN - Link 2 |
an-a05n01 IFN - Link 2 |
an-pdu01 | an-ups01 | an-striker02 BCN - Link 2 |
an-striker02 IPMI |
an-pdu03 | an-striker02 IFN - Link 2 |
||||||||||||||||||||||
X2 (2/2/2) | X4 (2/2/4) | X6 (2/2/6) | X8 (2/2/8) | 2 (2/1/2) | 4 (2/1/4) | 6 (2/1/6) | 8 (2/1/8) | 10 (2/1/10) | 12 (2/1/12) | 14 (2/1/14) | 16 (2/1/16) | 18 (2/1/18) | 20 (2/1/20) | 22 (2/1/22) | 24 (2/1/24) | 26 (2/1/26) | 28 (2/1/28) | 30 (2/1/30) | 32 (2/1/32) | 34 (2/1/34) | 36 (2/1/36) | 38 (2/1/38) | 40 (2/1/40) | 42 (2/1/42) | 44 (2/1/44) | 46 (2/1/46) | 48 (2/1/48) | |||
an-a05n02 BCN - Link 2 |
an-a05n02 SN - Link 2 |
an-a05n02 IFN - Link 2 |
an-pdu02 | an-ups02 | an-striker02 BCN - Link 2 |
an-pdu04 | an-striker02 BCN - Link 2 |
Uplink 2 | ||||||||||||||||||||||
VID 100 | VID 200 | VID 300 | VID 100 | VID 300 |
Understanding Brocade Logical Port Numbers
Brocade uses the follow scheme for naming their ports:
- stack ID/module/port
The Stack ID is simply the integer representing the ID number shown when you run 'show stack'.
The module number is static across all switches. They are:
- 1: Standard RJ-45 1 Gbps copper ports.
- 2: Ports used for stacking. Typically these are only used for stacking.
- 3: The SFP+ fiber or copper ports that normally run at 1 Gbps but can be licensed to run at 10 Gbps.
The port number is the simple integer representing the port. This is the number found above or below the physical port on the switch.
You see these x/y/z numbers in the table above, and they will be the method used below to identify ports and port ranges.
Forming the VLANs
To start, lets take a look at the current VLAN configuration.
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#show vlan
Total PORT-VLAN entries: 1
Maximum PORT-VLAN entries: 64
Legend: [Stk=Stack-Id, S=Slot]
Not much!
ICX6610-48 Switch(config)#vlan 100 name bcn
The BCN spans SFP ports 1 and 2 (1/3/1 to 1/3/1, 2/3/1 to 2/3/1) and copper ports 1 through 16 (1/1/1 to 1/1/16, 2/1/1 to 2/1/16) will be assigned to this VLAN. We can do this in one command.
ICX6610-48 Switch(config-vlan-100)#untag ethernet 1/3/1 to 1/3/2 ethernet 2/3/1 to 2/3/2 ethernet 1/1/1 to 1/1/16 ethernet 2/1/1 to 2/1/16
Added untagged port(s) ethe 1/1/1 to 1/1/16 ethe 1/3/1 to 1/3/2 ethe 2/1/1 to 2/1/16 ethe 2/3/1 to 2/3/2 to port-vlan 100.
The SN spans just four ports, all of which are on the SFP+ ports. They are 1/3/3 to 1/3/4 and 2/3/3 to 2/3/4.
ICX6610-48 Switch(config-vlan-100)#vlan 200 name sn
ICX6610-48 Switch(config-vlan-200)#untag ethernet 1/3/3 to 1/3/4 ethernet 2/3/3 to 2/3/4
Added untagged port(s) ethe 1/3/3 to 1/3/4 ethe 2/3/3 to 2/3/4 to port-vlan 200.
Finally, the biggest VLAN. We're going to allocate the last four SFP+ ports on both switch and copper ports 17 through 48 on both as well.
ICX6610-48 Switch(config-vlan-200)#vlan 300 name ifn
ICX6610-48 Switch(config-vlan-300)#untag ethernet 1/3/5 to 1/3/8 ethernet 2/3/5 to 2/3/8 ethernet 1/1/17 to 1/1/48 ethernet 2/1/17 to 2/1/48
Added untagged port(s) ethe 1/1/17 to 1/1/48 ethe 1/3/5 to 1/3/8 ethe 2/1/17 to 2/1/48 ethe 2/3/5 to 2/3/8 to port-vlan 300.
Done! Let's see what it looks like now:
ICX6610-48 Switch(config-vlan-300)#exit
ICX6610-48 Switch(config)#show vlan
Total PORT-VLAN entries: 4
Maximum PORT-VLAN entries: 64
Legend: [Stk=Stack-Id, S=Slot]
PORT-VLAN 1, Name DEFAULT-VLAN, Priority level0, Spanning tree On
Untagged Ports: None
Tagged Ports: None
Uplink Ports: None
DualMode Ports: None
Mac-Vlan Ports: None
Monitoring: Disabled
PORT-VLAN 100, Name bcn, Priority level0, Spanning tree On
Untagged Ports: (U1/M1) 1 2 3 4 5 6 7 8 9 10 11 12
Untagged Ports: (U1/M1) 13 14 15 16
Untagged Ports: (U1/M3) 1 2
Untagged Ports: (U2/M1) 1 2 3 4 5 6 7 8 9 10 11 12
Untagged Ports: (U2/M1) 13 14 15 16
Untagged Ports: (U2/M3) 1 2
Tagged Ports: None
Uplink Ports: None
DualMode Ports: None
Mac-Vlan Ports: None
Monitoring: Disabled
PORT-VLAN 200, Name sn, Priority level0, Spanning tree On
Untagged Ports: (U1/M3) 3 4
Untagged Ports: (U2/M3) 3 4
Tagged Ports: None
Uplink Ports: None
DualMode Ports: None
Mac-Vlan Ports: None
Monitoring: Disabled
PORT-VLAN 300, Name ifn, Priority level0, Spanning tree On
Untagged Ports: (U1/M1) 17 18 19 20 21 22 23 24 25 26 27 28
Untagged Ports: (U1/M1) 29 30 31 32 33 34 35 36 37 38 39 40
Untagged Ports: (U1/M1) 41 42 43 44 45 46 47 48
Untagged Ports: (U1/M3) 5 6 7 8
Untagged Ports: (U2/M1) 17 18 19 20 21 22 23 24 25 26 27 28
Untagged Ports: (U2/M1) 29 30 31 32 33 34 35 36 37 38 39 40
Untagged Ports: (U2/M1) 41 42 43 44 45 46 47 48
Untagged Ports: (U2/M3) 5 6 7 8
Tagged Ports: None
Uplink Ports: None
DualMode Ports: None
Mac-Vlan Ports: None
Monitoring: Disabled
Perfectly perfect. Save the changes and then we're done.
ICX6610-48 Switch(config)#write memory
Write startup-config done.
Automatic copy to member units: 2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Changing a Port's VLAN Assignment
In order to change a port from one VLAN to another, it must first to untagged as VLAN ID 1, then it can be re-assigned to the new VLAN ID.
### (config-vlan-200) no untag ethernet 2/1/15 to 2/1/24
### (config-vlan-200) show vlan
Note: A port in VID 1 will simply change to the newly assigned VID. Ports in other VIDs need to be reset with no untag ... before reconfiguring for the new VLAN. |
Pseudo Stacking on ICX6430-C12
To share one uplink between multiple VLANs (to act like a stack);
config terminal
an-s05(config)#vlan 100
an-s05(config-vlan-100)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 100.
an-s05(config-vlan-100)#vlan 200
an-s05(config-vlan-200)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 200.
an-s05(config-vlan-200)#vlan 300
an-s05(config-vlan-300)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 300.
To prevent switch loops when plugging in both C2.
an-s05(config-vlan-300)#spanning-tree rstp
Trunking
Passive Trunk
This is used when the connected switch does not support LACP.
Note: Configure with only one cable connected into the trunk ports. |
# config terminal
## (config) trunk ethernet 1/1/24 ethernet 2/1/24
Trunk will be created in next trunk deploy.
## (config) trunk deploy
## (config) write memory
Active Trunk
This is used if you can create an LACP on the client's switch.
Note: Configure with only one cable connected into the trunk ports. |
# config terminal
## (config) lag <i>lag-name</i> dynamic
## (config-lag-<i>lag-name</i>) ports ethernet 1/1/23 ethernet 2/1/23
## (config-lag-<i>lag-name</i>) lacp-timeout short
## (config-lag-<i>lag-name</i>) primary-port 1/1/23
## (config-lag-<i>lag-name</i>) deploy
## (config-lag-<i>lag-name</i>) write mem
## exit
## show lag brief
Total number of LAGs: 1
Total number of deployed LAGs: 1
Total number of trunks created:1 (123 available)
LACP System Priority / ID: 1 / 609c.9f7b.4960
LACP Long timeout: 90, default: 90
LACP Short timeout: 3, default: 3
LAG Type Deploy Trunk Primary Port List
switch1 dynamic Y 1 1/1/23 e 1/1/23 e 2/1/23
Key Management
To get a license, you must purchase the license from a Brocade reseller. With it, you will get a spreadsheet containing a TRANSACTION KEY.
To convert this into a loadable license file, you will need to get the switch's 'LID', then create an account on "My Brocade". You can then combine the LID and the TRANSACTION KEY and Brocade will email you the license key.
To get the LID;
ICX6610-48 Switch#show version
Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
UNIT 1: compiled on May 10 2013 at 16:48:26 labeled as FCXS07300f
(5370497 bytes) from Primary /foundry/FGS/os/FCXS07300f.bin
SW: Version 07.3.00fT7f1
UNIT 2: compiled on May 10 2013 at 16:48:26 labeled as FCXS07300f
(5370497 bytes) from Primary /foundry/FGS/os/FCXS07300f.bin
SW: Version 07.3.00fT7f1
Boot-Monitor Image size = 370555, Version:07.3.02T7f5 (grz07302)
HW: Stackable ICX6610-48
==========================================================================
UNIT 1: SL 1: ICX6610-48 48-port Management Module
Serial #: xxxxxxxxxxx
License: BASE_SOFT_PACKAGE (LID: yyyyyyyyyyy)
P-ENGINE 0: type E02B, rev 01
P-ENGINE 1: type E02B, rev 01
==========================================================================
UNIT 1: SL 2: ICX6610-QSFP 10-port 160G Module
==========================================================================
UNIT 1: SL 3: ICX6610-8-port Dual Mode(SFP/SFP+) Module
==========================================================================
UNIT 2: SL 1: ICX6610-48 48-port Management Module
Serial #: aaaaaaaaaaa
License: BASE_SOFT_PACKAGE (LID: bbbbbbbbbbb)
P-ENGINE 0: type E02B, rev 01
P-ENGINE 1: type E02B, rev 01
==========================================================================
UNIT 2: SL 2: ICX6610-QSFP 10-port 160G Module
==========================================================================
UNIT 2: SL 3: ICX6610-8-port Dual Mode(SFP/SFP+) Module
==========================================================================
800 MHz Power PC processor 8544E (version 0021/0023) 400 MHz bus
65536 KB flash memory
512 MB DRAM
STACKID 1 system uptime is 1 days 17 hours 8 minutes 17 seconds
STACKID 2 system uptime is 22 hours 36 minutes 24 seconds
The system : started=warm start reloaded=by "reload"
My stack unit ID = 1, bootup role = active
With the TRANSACTION KEY and LID, and having logged into Brocade Software Portal;
- Hover over the top-left 'License Management' button. A drop-down menu will appear. Hover over 'Brocade IP/ADP'. Another pop-out menu will appear, click on 'License Generation with Transaction Key'.
- A form will appear. Fill it our as instructed. Check to accept the EULA and then click 'Add'.
- IF YOU ARE ADDING TWO LICENSES TO ONE SWITCH:
- Fill out the LID and Transaction key for the next license, again accept the EULA and click 'Add' again.
- Once all licenses for the specified switch are added, click on 'Generate'.
- If all was well, you will be shown a summary and an email with the license will be emailed to you.
Repeat as needed for each switch.
Installing Keys
Once you get the license file from Brocade, copy the key to the root of your TFTP server (/var/lib/tftpboot/ on EL6).
Note the LID number and which stack ID. In this case, I renamed the license files so that an-switch01_XXXXXXXXXXX.xml, where XXXXXXXXXXX is the switch's LID. In the example below, I will load two licenses, one for either switch in the stack.
ICX6610-24 Switch#copy tftp license 10.255.255.254 an-switch01_XXXXXXXXXXX.xml unit 1
Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
T=1d20h6m27.7: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
ICX6610-24 Switch#copy tftp license 10.255.255.254 an-switch02_XXXXXXXXXXX.xml unit 2
Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
Copy software license to stack unit 2 success
Flash Memory Write (8192 bytes per dot) .
T=1d20h7m50.1: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
ICX6610-24 Switch#show license
Index License Name Lid License Type Status License Period License Capacity
Stack unit 1:
1 ICX6610-10G-LIC-POD xxxxxxxxxxx Normal Active Unlimited 8
Stack unit 2:
1 ICX6610-10G-LIC-POD aaaaaaaaaaa Normal Active Unlimited 8
write memory
Repeat as needed.
Enable 10 Gbps Ports
After installing license files to upgrade the eight 1 Gbps SFP+ ports to run as 10 Gbps, we need to actually enable the ports. This may seem silly, but consider that the upgrades are sold in lots of 4-ports at a time. This step would allow you to specify which four ports were upgraded. In our case, we upgraded them all.
ICX6610-48 Switch#config terminal
ICX6610-48 Switch(config)#interface ethernet 1/3/1 to 1/3/8
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#speed-duplex 10g-full
This will take a minute, please wait.
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#interface ethernet 2/3/1 to 2/3/8
ICX6610-48 Switch(config-mif-2/3/1-2/3/8)#speed-duplex 10g-full
ICX6610-48 Switch(config-mif-2/3/1-2/3/8)#exit
If you (accidentally) use a 1 Gbps SFP+ cable, the upgrade will likely throw an error like the one below:
U2-MSG: INFO: 2/3/4: optics <-> speed mismatch. Replace with SFP+ to enable link.
U2-MSG: INFO: 2/3/4: optics <-> speed mismatch. Replace with SFP+ to enable link.
You can reduce the port speed to make it work (albeit at 1 Gbps):
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#interface ethernet 2/3/4
ICX6610-48 Switch(config-if-e10000-2/3/4)#speed-duplex 1000-full-master
When done, save your changes.
ICX6610-48 Switch(config)#write memory
Write startup-config done.
Automatic copy to member units: 2
ICX6610-48 Switch(config)#Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Deleting Keys
If you need to remove a key (ie: replacing a demo license), you can do so thusly:
ICX6610-24 Switch#license delete unit 1 index 1
ICX6610-24 Switch#show license
License record empty
Replacing a Switch
Warning: The switch that is the stack master will overwrite the configuration of the stack slave. So be sure to flash the firmware to match the existing switch, license the ports if needed and enable stacking on the replacement switch while it is stand-alone. Power it off, plug in the stack cables and then apply power. When it boots, it's config should be replaced with the good switch's configuration. To be safe, in an Anvil!, withdraw a node before reforming the stack. |
Warning: You must contact Brocade to move the licenses! |
If a switch needs to be replaced, we may need to "de-license" the old switch.
Call Brocade support (1-800-752-8061) and use the case number the switch was replaced under. Confirm with them the LID of the switch being replaced (the one that the license will be removed from) and the LID of the new/replacement switch.
With the switch being returned, there is no need to prove the old license is removed as you will be returning the switch. If you will NOT be returning the switch, then you will need to provide a show license before and after deleting the old license in order for the license to be reissued. This is a rare case and the Brocade technician will walk you through the process should it be required.
They will email you the replacement license, at which point you will license the replacement switch as if it were a new switch.
Note: Depending your email client, you may need to request the XML license file be attached separately. |
Checking the Firmware
Before you proceed, make sure the Firmware is the same version as the stack master. If not, upgrade (or downgrade) the RMAed switch to match.
Licensing the Switch
Once you have the XML file, proceed from here.
Adding the Switch to the Stack
For this step, we want to enable stacking on the new switch and nothing more.
stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/6 is not available.
write memory
Write startup-config done.
ICX6610-48 Switch(config)#Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Note: In the example below, switch 1 is being replaced. |
At this point, switch to the production switch (which ever isn't being replaced). Connect the newly flashed and licensed replacement switch and you should see the configuration automatically upload to the newly replaced switch.
ICX6610-48 Switch#T=4d4h15m31.2: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 0,
T=4d4h15m32.2: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 0,
Detect stack unit 1 has different startup config flash, will synchronize it
T=4d4h15m34.0: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 1,
Detect stack unit 1 has different startup config flash, will synchronize it
reset unit 1: jumbo mismatch. Act u2: 1, Mem u1: 0
reset unit 1: jumbo mismatch. Act u2: 1, Mem u1: 0
Unit 2 loses all neighbors.
Active unit 2 deletes u1 but keeps its static config.
Some time passes:
T=4d4h18m52.3: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 1,
Detect stack unit 1 has different startup config flash, will synchronize it
Done hot swap: active controller unit 2 sets unit 1 to Ready.
Synchronize startup config to stack unit 1
Flash Memory Write (8192 bytes per dot) .
Assigned unit 1 to be standby
start running config sync
Running config sync to standby is complete
At this point, recovery is complete.
Unconfigure Stack
If you boot a stacked switch on it's own, you will not have normal access to the switch configuration.
MEMBER]local-1@ICX6610-48 Switch>enable
No password has been assigned yet...
[MEMBER]local-1@ICX6610-48 Switch#
To clear the stack config and restore the switch to standard mode, run:
stack unconfigure clean
This unit will delete all config files and boot up as a clean unit. Are you sure? (enter 'y' or 'n'): y
Remove startup config and stacking files. Will reload as a clean unit
[MEMBER]local-1@ICX6610-48 Switch#HRebooting(1)...
Multicast Config
ICX6610-24 Switch#config terminal
ICX6610-24 Switch(config)#vlan 300
ICX6610-24 Switch(config-vlan-300)#multicast passive
ICX6610-24 Switch(config-vlan-300)#multicast version 2
Done
Resetting Lost Password
If you've lost the system password, you will need physical access to the switch.
Note: If you can't sit at your computer and press the reset button directly, ask someone to help with this next step as the timing is short. |
On the front of the switch will be a small "Reset" switch. To press this, you will need a very thin object in order to press the button, like a small paper clip, needle or so on.
During the boot process, press b when you see the Enter 'b' to stop at boot monitor: prompt.
Enter 'b' to stop at boot monitor: 0
ICX64XX-boot>> no password
OK! Skip password check when the system is up.
ICX64XX-boot>> boot system flash primary
Usage:
boot - boot default, i.e., run 'bootcmd'
ICX64XX-boot>> boot_primary
Booting image from Primary
## Booting image at 00007fc0 ...
Created: 2013-04-27 3:19:57 UTC
Data Size: 10552120 Bytes = 10.1 MB
Load Address: 00008000
Entry Point: 00008000
Verifying Checksum ... OK
OK
On next boot, you will be able to log into the switch without a password.
Reset to Factory Defaults
Note: This will erase any loaded licenses. If you have loaded licenses, be sure you have them backed up before proceeding. |
At the command prompt, do:
SHESW11#erase startup-config
Erase startup-config Done.
dhcp server lease database is also removed
Warning: Do not write memory! This will reload the running configuration back onto the system. |
SHESW11#reload
Are you sure? (enter 'y' or 'n'):
Sent SIGKILL to all processes
Requesting system reboot
Restarting syste
On the next boot, you should have an as-new system.
SNMP
ICX-6430-C12
To enable read-write access of MIB data;
an-s06(config)#snmp-server community public rw
Notes
Port numbering syntax is:
<stack>/<module>/<port>
Module numbering;
- 1; Copper 1 Gbit
- 2; Fibre stack
- 3; 10 Gbps fibre
View the port status:
ICX6610-48 Switch(config)#show interfaces brief
Port Link State Dupl Speed Trunk Tag Pvid Pri MAC Name
1/1/1 Down None None None None No 1 0 cc4e.24b9.4b74
1/1/2 Down None None None None No 1 0 cc4e.24b9.4b75
1/1/3 Down None None None None No 1 0 cc4e.24b9.4b76
1/1/4 Down None None None None No 1 0 cc4e.24b9.4b77
1/1/5 Down None None None None No 1 0 cc4e.24b9.4b78
1/1/6 Down None None None None No 1 0 cc4e.24b9.4b79
1/1/7 Down None None None None No 1 0 cc4e.24b9.4b7a
1/1/8 Down None None None None No 1 0 cc4e.24b9.4b7b
1/1/9 Down None None None None No 1 0 cc4e.24b9.4b7c
1/1/10 Down None None None None No 1 0 cc4e.24b9.4b7d
1/1/11 Down None None None None No 1 0 cc4e.24b9.4b7e
1/1/12 Down None None None None No 1 0 cc4e.24b9.4b7f
1/1/13 Down None None None None No 1 0 cc4e.24b9.4b80
1/1/14 Down None None None None No 1 0 cc4e.24b9.4b81
1/1/15 Down None None None None No 1 0 cc4e.24b9.4b82
1/1/16 Down None None None None No 1 0 cc4e.24b9.4b83
1/1/17 Down None None None None No 1 0 cc4e.24b9.4b84
1/1/18 Down None None None None No 1 0 cc4e.24b9.4b85
1/1/19 Down None None None None No 1 0 cc4e.24b9.4b86
1/1/20 Down None None None None No 1 0 cc4e.24b9.4b87
1/1/21 Down None None None None No 1 0 cc4e.24b9.4b88
1/1/22 Down None None None None No 1 0 cc4e.24b9.4b89
1/1/23 Down None None None None No 1 0 cc4e.24b9.4b8a
1/1/24 Down None None None None No 1 0 cc4e.24b9.4b8b
1/1/25 Down None None None None No 1 0 cc4e.24b9.4b8c
1/1/26 Down None None None None No 1 0 cc4e.24b9.4b8d
1/1/27 Down None None None None No 1 0 cc4e.24b9.4b8e
1/1/28 Down None None None None No 1 0 cc4e.24b9.4b8f
1/1/29 Down None None None None No 1 0 cc4e.24b9.4b90
1/1/30 Up Forward Full 1G None No 1 0 cc4e.24b9.4b91
1/1/31 Up Forward Full 1G None No 1 0 cc4e.24b9.4b92
1/1/32 Down None None None None No 1 0 cc4e.24b9.4b93
1/1/33 Up Forward Full 1G None No 1 0 cc4e.24b9.4b94
1/1/34 Up Forward Full 1G None No 1 0 cc4e.24b9.4b95
1/1/35 Up Forward Full 1G None No 1 0 cc4e.24b9.4b96
1/1/36 Up Forward Full 1G None No 1 0 cc4e.24b9.4b97
1/1/37 Up Forward Full 1G None No 1 0 cc4e.24b9.4b98
1/1/38 Up Forward Full 1G None No 1 0 cc4e.24b9.4b99
1/1/39 Down None None None None No 1 0 cc4e.24b9.4b9a
1/1/40 Down None None None None No 1 0 cc4e.24b9.4b9b
1/1/41 Up Forward Full 1G None No 1 0 cc4e.24b9.4b9c
1/1/42 Up Forward Full 1G None No 1 0 cc4e.24b9.4b9d
1/1/43 Up Forward Full 1G None No 1 0 cc4e.24b9.4b9e
1/1/44 Down None None None None No 1 0 cc4e.24b9.4b9f
1/1/45 Down None None None None No 1 0 cc4e.24b9.4ba0
1/1/46 Up Forward Full 1G None No 1 0 cc4e.24b9.4ba1
1/1/47 Down None None None None No 1 0 cc4e.24b9.4ba2
1/1/48 Up Forward Full 1G None No 1 0 cc4e.24b9.4ba3
1/2/1 Up Forward Full 40G None No N/A 0 cc4e.24b9.4ba5
1/2/2 Up Forward Full 10G None No N/A 0 cc4e.24b9.4ba6
1/2/6 Up Forward Full 40G None No N/A 0 cc4e.24b9.4ba7
1/2/7 Up Forward Full 10G None No N/A 0 cc4e.24b9.4ba8
1/3/1 Down None None None None No 1 0 cc4e.24b9.4ba9
1/3/2 Up Forward Full 10G None No 1 0 cc4e.24b9.4baa
1/3/3 Down None None None None No 1 0 cc4e.24b9.4bab
1/3/4 Down None None None None No 1 0 cc4e.24b9.4bac
1/3/5 Down None None None None No 1 0 cc4e.24b9.4bad
1/3/6 Up Forward Full 10G None No 1 0 cc4e.24b9.4bae
1/3/7 Down None None None None No 1 0 cc4e.24b9.4baf
1/3/8 Down None None None None No 1 0 cc4e.24b9.4bb0
mgmt1 Down None None None None No None 0 cc4e.24b9.4b74